PRODUCTS CENTER

Committed To Vibration Monitoring And Analysis Of Sensors And Rotating Machinery

Products

VMS1160 explosion-proof vibration transmitter


Contact Us
Back

0
<
>

Product Details

 

overview

The transmitter is an explosion-proof vibration velocity transmitter, which provides 4-20mA current signal output, which is proportional to the vibration velocity of the bearing bush or bearing seat of the rotating machinery. It automatically collects the vibration signal on the machine, and uses the converted analog signal for PLC, DCS and DEH systems, etc. The current range of 4-20mA is proportional to the vibration measurement value and corresponds to the measurement range are connected through the "analog output" cable terminal.

application

For rotating and reciprocating machines such as: fans, centrifuges, pumps, electric motors, gear reducers, industrial fans, heat exchangers/cooling towers, air-cooled island fans, generators, piston compressors, centrifugal compressors, gravel Machine/coal mill, compressor, pump, coal mill, etc.

Technical Parameters

Signal

Measurement parameters

Intensity (Trms)

number of channels

single channel

precision

±1%FS@25℃

Frequency Range

10Hz - 1KHz

Measuring range

0 - 20.0mm/s ,[4mA is equal to 0.0 mm/s and 20mA is equal to 20.0mm/s (default)], can be customized within the range of 0 - 50.0mm/s

output

4~20mA current

Large load 750Ω, ±0.1%FS@25℃

physics

diameter

55mm

high

108mm

material

Stainless steel

Output Interface

two-position terminal

Explosion-proof grade

Exd II CT6

mounting thread

M10 internal threaded hole

protection

IP68

weight

500g

Connector Wiring Conventions

+24V: 4-20mA positive loop, Iout: 4-20mA negative loop, terminal (Shield) = shell ground

environment

operating temperature

-40℃~+100℃

stored temperature

-45℃~+110℃

humidity

≤100% non-condensing, non-immersion

powered by

supply voltage

18 ~30 Vdc (Typical 24Vdc)

ordering information

VMS 1160 explosion-proof vibration transmitter

order number

Measuring rangeA

Other B

describe

VMS1160-Ax-B00

10.0≤A≤50.0mm/s, default measurement range: 0-20.0mm/s. For example: A20.0=measurement range: 0-20.0mm/s.

00: no requirement

The transmitter output connector is a terminal block

connection cable

order number

Cable length A

Other B

describe

VMS602901-Ax-B00

1m≤A≤300m, increment by 0.5m, default 3m.

For example: A2.5 = cable length 2.5 meters.

00: no requirement

2-core shielded cable, armored with plastic, armored diameter 8mm, <120℃< p="">

Attachment 1: Mounting Bolts

order number

describe

VMS604403

M10 to M10×1.5×15(L)






 


JIANGLING TECHNOLOGY
Service Hotline:
0510-80283688
E-mail:
jl80283688@163.com
Address:
No. 272, Changshan Avenue, Yunting Street, Jiangyin City
            
All rights reserved.:Jiangsu Jiangling Measurement & Control Technology stock Co., Ltd        苏ICP备18059736号-2